The current in the neutral is displayed if the neutral ct is set as internal or external see ineutral a settings. All other trademarks are the property of their respective owners. Square d by schneider electric hom2448m100pcvp homeline 100 amp 24space 48circuit indoor main breaker load center with cover value pack plugon neutral ready, 4. Dec 10, 2014 square d added increased emcefi immunity to micrologic trip units built after december of 2005 following reports of nuisance trips during switching operations. Apr 09, 2015 square d by schneider electric 80,950 views. Micrologic 0 trip units for molded case switches advanced micrologic trip units consist of two families of electronic trip units. Schneider electric masterpact nt and nw universal power. Square d schneider electric s164a micrologic circuit. Mds616 magnum ds by cutlerhammer sierra circuit breakers. Schneider electric masterpact nt and nw universal power circuit. Square d micrologic type s circuit breaker function test kit complete with power and communication cables and user manuals.
Part 2 micrologic trip system provides information about the electronic trip system used in these circuit breakers. Masterpact mtz micrologic x control unit user guide lk mobile. Pe and px electronic trip circuit breakers with micrologic. Toggle navigation 0 go back all categories categories breaker panels 0 breaker panels. Shop micrologic circuit breaker trip unit, model 6. For this reason, the trip unit should be replaced if it was manufactured prior to december 2005. Available circuit breakers catalog prefix frame sizes a le, lx page 24 600 me, mx page 26 800. Tutorial for installing a replacement lithium battery part number s33593 powering only the leds on the micrologic 3.
Square d cim3f micrologic communications adapter accessory. Micrologic fullfunction trip units prior to series 3 table 2 lists trip unit settings for electronic trip circuit breakers produced by square d with micrologic fullfunction trip units prior to series 3, series a or series b. Masterpact circuit breakers are available in square d or schneider electric brands. Groundfault trip with programmable ground fault alarm available on 6. Use two paltb terminal pad kits for mounting each circuit breaker one for each end. New square d nw40h2 4000a masterpact breaker micrologic 6. Masterpact nw lowvoltage powerinsulated case circuit. Micrologic a and e control units user manual version 07. Jun 09, 2015 you cannot use the square d fullfunction test kit fftk, handheld test kit hhtk or universal test set uts3 to test the new micrologic 356 trip units found on powerpact h, j and l frame molded case breakers. Ya5kkr64a3cxxxxxxa square d masterpact nw40h2 ya5kkr64a3cxxxxxxa circuit breaker pn. And there have been a couple recalls on those trip units, one involving the battery, one involving false tripping. For our vertical mounted micrologic electronic trip units, some have the ability to swap out their unit plug and have their trip characteristics adjusted.
Moulded case circuit breaker micrologic series b trip systems. Square d nw20h1 2000a lv masterpact eo circuit breaker. You will instead need the schneider electric pocket tester s434206 or uta tester strv00910 to secondary test these trip units. Overload alarm, the load exceeds 105% of the ir setting of the longtime protection. Moulded case circuit breaker micrologic series b trip. This table applies to all micrologic fullfunction trip. S33595 square d circuit breaker parts and accessories. Micrologic trip unit features standardfunction circuit breakers fullfunction circuit breakers d e t a r % 0 8 true rootmean square rms sensing. Car boat 30a300a amp circuit breaker fuse with manual reset switch 12v48vdc. Masterpact mtz1 circuit breakers and switchdisconnectors user guide. Powerpact h, j, and lframe trip units schneider electric. Nw20h1 used lowvoltage power circuit breaker 2000 amps frame 1200 a trip shunt trip motor mechanism lsig includes copper bus bar stabs on back 3 pole 5060 hz interrupting rating. Part 4 accessories lists the accessories available for use with electronic trip insulated case circuit breakers.
Micrologic electronic trip systems 06ct0001 masterpact. Tutorial for configuring trip point amperage and delay settings on the micrologic 5. Micrologic series b trip system fullfunction features. All products solutions lifecycle services partners square d digestplus online catalog. Square d nw25h1 2500a lsig masterpact circuit breaker w.
Find s33595, circuit breaker parts and accessories by square d at widespread electrical sales. Micrologic 0, 1, 2, and 3 trip unitsuser guide unidades. Paragraph 23095 c of the national electrical code requires that all equipment groundfault. Micrologic 5 and 6 trip units for distribution protection micrologic 6 em trip units for motor circuit protection this manual describes operation of the micrologic. The test button is used to test the groundfault protection for micrologic 6. Masterpact nw drawout circuit breakers lowvoltage power circuit breaker insulated case circuit breaker iec rated circuit breaker iec extreme. All products include 2 year warranty, same day shipping. For information on other types of molded case circuit breakers manufactured by square d, see thermalmagnetic and magnetic only molded case circuit breakers catalog 0601ct9101.
Overload prealarm, the load exceeds 90% and is lower than 105% of the ir setting of the longtime protection. The number for that phase is presented in a square. If the micrologic x control unit is not powered, the trip cause leds go off after four hours. Remote racking with a square d nw circuit breaker duration. Click here to request a quote squared nw40h12circuitbreaker micrologic 60plsigsquare d ya5kkr64a3xxxxxxa ci. After this period, press the testreset button to light them again. Square d equipment, terminal pads are required to provide electrical spacing for lugs and mounting hardware. Square d nw25h1 2500a lsig masterpact circuit breaker w 2500. Square d offers the seals below to restrict access to trip unit once settings are selected.
Micrologic series b trip unit accessories complying with nec the national electrical code, section 2406b exception allows conductor ampere ratings equal to the selected longtime pickup setting. Square d masterpact nw40h2 ya5kkr64a3cxxxxxxa circuit. Micrologic advanced protection ap troubleshooting guide. Catalog numbering system when ordering square d electronic trip circuit breakers, include circuit breaker family, poles, voltage rating, ampere rating and trip unit suffix. Schneider electric, square d, masterpact, micrologic, enerlinx and ecoreach are trademarks owned by schneider electric industries sas or its affiliated companies. Part 3 sensorampere ratings describes the insulated case circuit breakers available from square d. The rating of the circuit breaker in this example is 2000 a. Square d nw20h1 2000a lv masterpact eo circuit breaker 1200a. Includes all features listed for micrologic ammeter trip unit, as well as. This table applies to all micrologic fullfunction trip units which do not have two rows of rotary switches. Micrologic x control unit description masterpact mtz. Micrologic e nove ridici jednotky pro jistice compact ns a. Schneider electric micrologic s144a circuit breaker micro.